Product/Process:Back-O-Kill -a pot for complete
disinfection of water.
Application/use:
To obtain potable water free of microbial infection; toxic
contaminants like leachates of metals viz. Fe, Cr, Sn, Zn,
Pb, Ni within WHO permissible limits.
Salient Features
of Process/Technology: The device works on the principle
of anodic oxidation. Passage of a small current in water produces
active oxygen thereby destroying the microorganisms. The equipment
consists of a chemical reactor cell powered through DC current
or 22 VAC supply. The instrument can be preset to threshold
energy level and for required treatment time. The user is
informed of completion through an alarm as well as UV visual
indicator.
Status of Commercialisation:
Commercialised.
Minimum Economic
Unit Size: 8-10 L water/batch
Equipment and
Machinery: Bact-O-Kill available from CSIR licensee.
Raw Materials:
Contaminated water required to be purified.