Energy
Techonologies - Chrome-Plating Waste Water Treatment
Introduction
The technology uses acid luminous Cu to replace cyanide
used in traditional copper-plating process and prevents
the pollution of cyanide. It also uses luminous Ni-Fe,
luminous Ni and may save 10-20% of Ni, an advanced active
technology to strengthen, cyanide used in the combining
force between plating layers, and uses waste active
matter to treat the chrome plating waste water, and
prevent electroplating pollution. Technical specifications
are CASS test : 24th; Combining strength = 12%; Smooth
finish; 590-606; Thickness of plating layers; Cu 15,
Ni-Fe 14, Cr 0.5; (Cr8+) in the discharged waste water:
0.5 mg/L.
Environmental Aspects:
Environment Friendly
Raw Materials: Cu and
Ni- about 6.3T, Chemical material - 35T to electroplate
50,000m2 products a year
Status Of Commercialization :
Patented & commercialised in China since
1992.
Asian and Pacific Centre for Transfer of Technology(APCTT)